ICRP Publication 145 : Adult Mesh-type Reference Computational Phantoms (Annals of the Icrp)

16,380 TWD
KPC會員價
14,742
English

產品說明

Following the issuance of new radiological protection recommendations in Publication 103 (ICRP, 2007), the Commission released, in Publication 110 (ICRP, 2009), the adult male and female voxel-type reference computational phantoms to be used for the calculation of the reference dose coefficients for both external and internal exposures. While providing more anatomically realistic representations of internal anatomy than the older stylised phantoms, the voxel phantoms have their limitations, mainly due to voxel resolution, especially with respect to small tissue structures (e.g. lens of the eye) and very thin tissue layers (e.g. stem cell layers in the stomach wall mucosa and intestinal epithelium). This report describes the construction of the adult mesh-type reference computational phantoms (MRCPs) that are the modelling counterparts of the Publication 110 voxel-type reference computational phantoms. The MRCPs include all source and target regions needed for estimating effective dose, even the µm-thick target regions in the respiratory and alimentary tract, skin, and urinary bladder, assimilating the supplemental stylised models. The MRCPs can be directly implemented into Monte Carlo particle transport codes for dose calculations, i.e. without voxelisation, fully maintaining the advantages of the mesh geometry.

Following the issuance of new radiological protection recommendations in Publication 103 (ICRP, 2007), the Commission released, in Publication 110 (ICRP, 2009), the adult male and female voxel-type reference computational phantoms to be used for the calculation of the reference dose coefficients for both external and internal exposures. While providing more anatomically realistic representations of internal anatomy than the older stylised phantoms, the voxel phantoms have their limitations, mainly due to voxel resolution, especially with respect to small tissue structures (e.g. lens of the eye) and very thin tissue layers (e.g. stem cell layers in the stomach wall mucosa and intestinal epithelium). This report describes the construction of the adult mesh-type reference computational phantoms (MRCPs) that are the modelling counterparts of the Publication 110 voxel-type reference computational phantoms. The MRCPs include all source and target regions needed for estimating effective dose, even the µm-thick target regions in the respiratory and alimentary tract, skin, and urinary bladder, assimilating the supplemental stylised models. The MRCPs can be directly implemented into Monte Carlo particle transport codes for dose calculations, i.e. without voxelisation, fully maintaining the advantages of the mesh geometry.

開放訂購

預計出貨時間約 3-4 weeks

我們已盡力確保庫存狀態正確,但偶爾仍可能會出現顯示狀態不符的情況。實際庫存狀況仍需以現場及供應商是否可提供為主。

訂單金額滿 1,000TWD 即可享有國內免運費優惠

折扣將於結帳時套用。

最近瀏覽過的項目

相關產品